Users Online: 445
Home Print this page Email this page
Home About us Editorial board Search Browse articles Submit article Ahead of Print Instructions Subscribe Contacts Special issues Login 
CASE REPORT
Year : 2017  |  Volume : 6  |  Issue : 1  |  Page : 72

A Novel Method for the Management of Anophthalmic Socket


1 Department of Maxillofacial Prosthodontics and Implantology, Gitams Dental College, Visakhapatnam, Andhra Pradesh, India
2 Department of Dentistry, Bidar Institute of Medical Sciences, Bidar, Karnataka, India
3 Department of Oral and Maxillofacial Surgery, Purvanchal Institute of Dental Sciences, Gorakhpur, Uttar Pradesh, India
4 Department of Maxillofacial Prosthodontics and Implantology, Peoples College of Dental Sciences and Research Centre, Bhopal, Madhya Pradesh, India

Correspondence Address:
Sunil Kumar Mishra
Department of Maxillofacial Prosthodontics and Implantology, Peoples College of Dental Sciences and Research Centre, Bhopal, Madhya Pradesh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/abr.abr_247_16

Rights and Permissions

An orbital defect causes severe facial asymmetry and disfigurement that result in an immense emotional trauma to the patient and is also associated with economic, esthetic, and psychological problems. A prosthetic replacement is the treatment of choice in helping individual to return to his normal life by producing an acceptable and lifelike appearance. This case report describes the critical areas of fabrication of ocular prosthesis for a patient with missing right eye due to trauma to eye ball in an accident. Patient had given a history of surgical enucleation of the eye 15 days after ocular trauma. A polymethyl methacrylate ocular prosthesis was planned. The technique described in this case report presents the use of both custom-made and stock eye shell in an attempt to include the benefits of both. A novel attempt was made to simulate eye movements and exact color matching to that of contralateral eye to provide a better and functional ocular prosthesis to the patient.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2692    
    Printed81    
    Emailed0    
    PDF Downloaded304    
    Comments [Add]    
    Cited by others 1    

Recommend this journal