Users Online: 18
Home Print this page Email this page
Home About us Editorial board Search Browse articles Submit article Ahead of Print Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2021  |  Volume : 10  |  Issue : 1  |  Page : 28

Value of D-dimer as a diagnostic marker of infection associated with orthopedic implants


1 Department of Orthopedic Surgery, Shohadaye Tajrish Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran
2 Department of Hand and Microsurgery, Panzdahe Khordad Hospital, Shahid Beheshti University of Medical Sciences, Tehran, Iran
3 Department of Orthopedics, Urmia University of Medical Sciences, Urmia, Iran

Correspondence Address:
Dr. Ali Tabrizi
Department of Hand and Microsurgery, Panzdahe Khordad Hospital, Tehran University of Medical Sciences, Karimkhan Street, Azodi Boulevard, Tehran 57157 81351
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/abr.abr_277_20

Rights and Permissions

Background: Recently, the D-dimer biomarker has gained the researchers' attention for predicting infections. We aimed to determine the relationship between this marker and other inflammatory markers involved in orthopedic implant-associated infections. Materials and Methods: In this study, all patients diagnosed with an orthopedic implant-associated infection were investigated in 3 years. The serum level of D-dimer, erythrocyte sedimentation rate (ESR), and C-reactive protein (CRP) was measured. Infection was diagnosed based on the clinical and culture results of biopsy samples. Results: The cultured microorganisms, detected in 26 patients with infections, included Staphylococcus aureus (n = 13, 50%), Staphylococcus epidermidis (n = 2, 7.7%), Klebsiella aerogenes (n = 8, 30.8%), and Pseudomonas aeruginosa (n = 3, 11. 5%). Based on laboratory findings, there was a significant difference in the CRP level and ESR (P = 0.001). Although the level of D-dimer was higher in infected patients, compared to the controls (992.6 ± 667.2 vs. 690.1 ± 250.2 ng/mL), the difference was not statistically significant. There was no significant correlation between the elevated D-dimer level and CRP level, whereas ESR had a positive correlation with the elevated D-dimer level (r = 0.6, P = 0.03). The sensitivity, specificity, and positive predictive value (PPV) of D-dimer in the prediction of infection were 65%, 57%, and 45%, respectively. Furthermore, the sensitivity, specificity, and PPV of CRP were 100%, 92.3%, and 95%, respectively, whereas the corresponding values for ESR were 85%, 69.2%, and 62%, respectively. Conclusion: Measurement of the serum D-dimer level is not efficient for the diagnosis of orthopedic implant-associated infections due to its low predictive value. Furthermore, there was no significant correlation between the serum D-dimer level and CRP.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed274    
    Printed20    
    Emailed0    
    PDF Downloaded54    
    Comments [Add]    

Recommend this journal