Users Online: 369
Home Print this page Email this page
Home About us Editorial board Search Browse articles Submit article Ahead of Print Instructions Subscribe Contacts Special issues Login 
ORIGINAL ARTICLE
Year : 2023  |  Volume : 12  |  Issue : 1  |  Page : 30

Comparison of the effectiveness of two types of commercial endotracheal tube holders, with the conventional method in a manikin model


1 Department of Emergency Medicine, Isfahan University of Medical Sciences, Isfahan, Iran
2 Al-Zahra Research Institute, Isfahan University of Medical Sciences, Isfahan, Iran

Correspondence Address:
Dr. Khatere Ghaznavi
Department of Emergency Medicine, Isfahan University of Medical Sciences, Isfahan
Iran
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/abr.abr_192_21

Rights and Permissions

Background: Endotracheal intubation is employed to create a safe airway in patients requiring mechanical ventilation. The relatively high prevalence rate of unplanned displacement of the endotracheal tube (ETT) can be associated with serious complications. This study was conducted to evaluate the effectiveness of a newly designed tube holder in Iran (Irafit), the Thomas ETT holder and the traditional method using adhesive tape. Materials and Methods: The present manikin-based study was performed on the human mannequin. For this purpose, the mannequin was first subjected to oral intubation by a skilled emergency medicine specialist. Then, three methods of adhesive tape, Irafit-ETT holder, and Thomas-ETT holder were used. The mean of displacement in width of the mouth, length of the ETT, and depth as well as ETT removal was recorded. Results: The results of the present study revealed that the displacement in depth was significantly less in the Irafit-ETT holder as compared with the other two groups following the application of a tug (P < 0.001). The displacement in the length of the ETT with and without the application of a tug was significantly less in the Irafit-ETT holder and Thomas-ETT holder groups as compared with the adhesive tape group (P < 0.001). Conclusion: According to the results of the present study, it can be stated that both ETT holder devices (Thomas vs. Irafit) were not distinct in terms of displacements in length and width; however, the Iranian model was more successful in minimizing the displacement in depth.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed130    
    Printed8    
    Emailed0    
    PDF Downloaded19    
    Comments [Add]    

Recommend this journal